GA10D系列 10~12瓦 4KVac隔离电压 稳压输出 交流对直流电源转换器

产品描述

功能&特点


  • 通用输入电压 90~264VAC。

  • 效率高达85%。

  • 短路/过载保护。

  • 塑胶外壳全封装。

  • 产品保固3年。

  • 符合RoHS认证。




Specifications Typical At TA = 25°C, Nominal Input Voltage And Rated Output Current Unless Otherwise Specified


Part Number Output Wattage Output Voltage Output Current Ripple & Noise Efficiency
(W) (VDC) (mA) (mV) max (Note) (TYP %)
GA10D-S03 6.6 3.3 2000 150 72
GA10D-S05 10.0 5 2000 150 75
GA10D-S10 10.0 10 1000 150 80
GA10D-S12 12.0 12 1000 150 82
GA10D-S15 12.0 15 800 150 82
GA10D-S24 12.0 24 500 150 85
GA10D-S36 12.0 36 330 240 85
GA10D-S48 12.0 48 250 240 85

Note:
1. Ripple & noise is measured by using 20 MHz bandwidth, measured with a 47uf paralleled with a high-frequency 0.47uf capacitor arcoss each output by full load.
2. Only GA10D-S05-A recognized by CB.



Input Specifications


Parameters Conditions Min Typ Max Units
Rated Input Voltage Vo, Io nom   100 ~ 240   Vac
Voltage Range Vo, Io nom AC in 90   264 Vac
DC in 120   370 Vdc
Line Frequency Vi nom, Io nom 47 50/60 63 Hz
Inrush Current Io nom Vi: 115VAC     10 A
Vi: 230VAC     20 A


Output Specifications


Parameters Conditions Min Typ Max Units
Output Voltage Accuracy

Vi nom,

 Io nom

3.3....V Models     ± 3 %
10....48V Models     ± 2 %
Minimum Load Vi nom 0     %
Line Regulation Io nom, Vi min....i max   ± 0.2   %
Load Regulation

Vi nom,

 Io min....o nom

3.3V Models   ± 1.0   %
5....48V Models   ± 0.5   %
Transient Recovery time Vi nom, Io nom =  ← → 0.5 Io nom   1000   us
Protection Over Load Above 110% rated output power
Protection type: Recovers automatically after fault condition is removed
Short Circuit Recovers automatically after fault condition is removed


General Specifications


Parameters Conditions Min Typ Max Units
Switching Frequency Vi nom, Io nom   65   KHz
Isolation Voltage Input / Output 4KVac / 5mA / 5Secs
Isolation Resistance Input / Output, @500 Vdc 100    
Operating Temperature Refer to Temperature Derating Graph -40   +70
Storage Temperature Non Operational -40   +105
Relative Humidity Vi nom,Io nom     95 % RH
Safety Standards Design refer to UL60950-1, IEC60950-1
EMI Conduction & Radiation EN55022, CLASS B (See Fig. 1 for recommended circuit)
EMS Immunity EN61000 (See Fig. 1 for recommended circuit)
Dimension L 50.8 x W 25.4 x H 23.5 mm
Cooling Free air convection



Dimension






 Files Download      GA10D-Series.pdf



Certification




产品询价

GA003/GB003/GC003系列 3瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA005/GB005/GC005系列 5瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA5E系列 5瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA5A系列 5~6瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA007系列 7瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA010系列 10瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA015系列 13~19瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA25D系列 20~27瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA025系列 25瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA025-SXX系列 14~25瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器

GA030系列 26~48瓦 3KVac隔离电压 稳压输出 交流对直流电源转换器